Pharmaceutical Sciences Faculty Publications
Comparison of Liquid Chromatography-Tandem Mass Spectrometry, RIA, and ELISA Methods for Measurement of Urinary Estrogens
Document Type
Article
Publication Date
1-1-2010
Journal Title
Cancer Epidemiology, Biomarkers & Prevention
ISSN
1538-7755
Volume
19
Issue
1
First Page
292
Last Page
300
DOI
10.1158/1055-9965.EPI-09-0643
PubMed ID
20056650
PubMed Central® ID
PMC2836837
Abstract
Absolute and relative concentrations of estrogens and estrogen metabolites are important for clinical decisions as well as for epidemiologic, experimental, and clinical research on hormonal carcinogenesis. RIA and ELISA are routinely used for measuring estrogen metabolites in blood and urine due to efficiency and low cost. Here, we compare absolute and ranked concentrations of estrone, estradiol, and estriol measured by indirect RIA and of 2-hydroxyestrone and 16alpha-hydroxyestrone measured by ELISA to the concentrations obtained using a novel liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, which measures 15 estrogen metabolites concurrently. We used overnight urine samples collected from control women (362 premenopausal and 168 postmenopausal) participating in a population-based case-control study of breast cancer among Asian American women ages 20 to 55 years. When comparing RIA or ELISA levels to LC-MS/MS, absolute concentrations for the five estrogen metabolites ranged from 1.6 to 2.9 and 1.4 to 11.8 times higher in premenopausal and postmenopausal women, respectively (all P < 0.0001). However, LC-MS/MS measurements were highly correlated [Spearman r (r(s)) = 0.8-0.9] with RIA and ELISA measurements in premenopausal women and moderately correlated (r(s) = 0.4-0.8) in postmenopausal women. Measurements of the 2-hydroxyestrone:16alpha-hydroxyestrone ratio, a putative biomarker of breast cancer risk, were moderately correlated in premenopausal women (r(s) = 0.6-0.7) but only weakly correlated in postmenopausal women (r(s) = 0.2). LC-MS/MS had higher intraclass correlation coefficients (> or =99.6%) and lower coefficients of variation (< or =9.4%) than ELISA (> or =97.2% and < or =14.2%) and RIA (> or =95.2% and < or =17.8%). Comparison with the LC-MS/MS method suggests that the widely used RIA and ELISA estrogen metabolite measures may be problematic, especially at low estrogen metabolite levels characteristic of postmenopausal women.
Keywords
Chromatography, liquid, estrogens, postmenopause, premenopause, radioimmunoassay, tandem mass spectrometry
Recommended Citation
Faupel-Badger, Jessica M.; Fuhrman, Barbara J.; Xu, Xia; Falk, Roni T.; Keefer, Larry K.; Veenstra, Timothy D.; Hoover, Robert N.; and Ziegler, Regina G., "Comparison of Liquid Chromatography-Tandem Mass Spectrometry, RIA, and ELISA Methods for Measurement of Urinary Estrogens" (2010). Pharmaceutical Sciences Faculty Publications. 276.
https://digitalcommons.cedarville.edu/pharmaceutical_sciences_publications/276